1. OZONE TEST: TEST CONDITION: (1). OZONE CONCENTRATION: 50pphm. (2). LASTING TIME: 72 HOURS. (3).TESTING TEMPERATURE: 40°C (4). ELONGATION: 20% RESULT: NO CRACKING VISABLE UNDER 10 TIMES MICROSCOPE. 2. RUBBER STRENGTH TEST: TEST RESULT: (1). ELONGATION RATE: 208% (2). FORCE OF EXTENSION: 30.47 Kg (REMARK: THE RAMDOM INSPECTION IS ACCORDING TO MIL-STD-105D STANDARD.) 3. LOW TEMPERATURE TEST: TEST CONDITION: (1). TEMPERATURE: -40°C (2). STRENTCH: 15%~20% (3). TIME: 24 HOURS. RESULT: NO CRACKING OR HARDNESS. 4. CORROSION TEST: TEST CONDITION: (1). SALT SPRAY ON WIPER FRAMES 96 HOURS. (2). SALT CONTENT: 40-60g/l. (3). PH: 6.5-7.2 (4). SPRAYING AMOUNT: 1-2 ml/80c?T/h RESULT: NO RUSSTING. 5. DURABILITY TEST: TEST CONDITION: (1).ROOM TEMPERATURE (2). LOW FREQUENCY CYCLE FOR 200,000 CYCLES: 34 cycles/min. (3). HIGH FREQUENCY CYCLE FOR 300,000 CYCLES: 50cycles/min. (4). OPERATION: WET: Water on 5-1/2 min. DRY: Water off 1/2 min. RESULT: (1). EFFECTIVE WIPE 75% AFTER 500,000 CYCLES. (2). REMAIN FUNCTIONAL AFTER 1,500,000 CYCLES. 6. WATER TRACE TEST: TEST CONDITION: (1). TEMPERATURE: ROOM TEMPERATURE. (2). LOW FREQUENCY CYCLE FOR 200,000 CYCLES:34 cycles/min. (3). HIGH FREQUENCY CYCLE FOR 300,000 CYCLES: 50 cycles/min. (4). 500,000 CYCLES RESULT: (1). NO LOOSENESS & JUMPING. (2). WATER TRACES: AFTER 500,000 CYCLES ﹛﹛﹛﹛﹛﹛﹛﹛﹛﹛﹛ CENTRAL AREA﹛﹛﹛﹛ EDGE AREA SLIM TRACE﹛﹛﹛﹛﹛﹛﹛﹛(0.5mm)﹛﹛﹛﹛﹛﹛﹛5 7 THICK TRACE﹛﹛﹛﹛﹛﹛﹛﹛(1mm)﹛﹛﹛﹛﹛﹛﹛ 2 3 WIDE TRACE﹛﹛﹛﹛﹛﹛﹛﹛(1-2mm)﹛﹛﹛﹛﹛﹛﹛0 2
REMARK:THE TEST IS ACCORDANCE TO J.I.S. JAPANESS INDUSTRIAL STANDARD |